8 1 2015 COOLFLEX CLX Subject to technical modifications Building entry Core bores cement pipe liners Wall leadthrough Core bores Outer casing D1 A Ø D mm mm mm 76 150 180 91 150 180 126 200 230 162 250 280 182 250 280 PE connection piece see sheet CLX 2 350 End cap see sheet CLX 2 365 COOLFLEX pipe see sheets CLX 2 115 D min 30 A D1 COOLFLEX Figures in mm Core bores Perfect bores are required for installation As hairline cracks may be present in the concrete or result from drilling it is advisable to seal the entire length of the borehole wall with suitable sealant such as AQUAGARD Tightness can only be guaranteed if this recommendation is followed Key 1 COOLFLEX 2 Sealing set single seal width 1 x 40 mm Shore hardness D35 3 Sealing set double seal width 2 x 40 mm Shore hardness D35 4 Liner pipe made of fiber cement or coated core bore Suitable for pressure from water up to 0 5 bar 80 mm 2 380