9 3 2015 CALPEX district heating pipe CPX Subject to technical changes Installation of house entry 1 525 1 Mark the distance x y z 1 cm from the end of the pipe 2 Cut the casing pipe with saw 3 Split the casing pipe with knife Note Don t damage the carrier pipe 4 Peel off the casing 5 Cut back remove the insulation along length X Y Z Note Don t damage the carrier pipe 6 Install the wall sealing ring 7 Carefully shrink on the pipe end closure according to the Raychem DHEC installa tion instruction 8 Install the fitting as per the enclosed installation instructions DUO screwed connector House connection ø 22 50 Y 80 mm ø 22 50 Z 180 mm Joint sleeve ø 22 50 Y 60 mm ø 22 50 Z 160 mm UNO compression joint House connection ø 22 50 X 140 mm ø 63 125 X 180 mm Joint sleeve ø 22 50 X 110 mm ø 63 110 X 140 mm ø 125 160 X 150 mm UNO screwed connector House connection ø 22 75 X 90 mm ø 90 110 X 140 mm Joint sleeve ø 22 75 X 70 mm ø 90 110 X 140 mm DUO compression joint House connection ø 22 50 Y Z 140 mm ø 63 Y Z 160 mm Joint sleeve ø 22 50 Y Z 110 mm ø 63 Y Z 140 mm Note Install the CPX Clip Shells according to the installation instruction CALPEX 10UNO DUO y zx 9 CALPEX