8 1 2015 Monitoring technology Visileak VSL Subject to technical changes Device description LMS 120 7 Accessories Item name Item number Description LMS 120 DE 21000076 LMS 120 with mains plug for Germany LMS 120 CH LMS 120 with mains plug for Switzerland Socket AD2 21000083 Socket for LMS 120 Monitoring end piece 21000081 Loop end plug Tab 6 Accessories 8 Technical data Requirements for voltage supply Voltage 100 240 VAC Power consumption max 100 mA Max power consumption on activation 6 A Output 6 W Housing specification Dimensions width x height x depth 182 x 180 x 90 mm Installation Wall instillation control cabinet installation screws Materials and colour Housing Polystyrene grey similar to RAL 7035 Lid Polycarbonate transparent Protection category IP 65 in accordance with EN 60529 Weight excl packaging 1 1 kg Measurement inputs specification Wire standards measurement wires Nordic 2 copper blank Brandes NiCr 5 7 m copper isolated Swiss copper blank copper isolated Potential separation Yes Alarm output specification Type of the alarm output Relay Max contact voltage 24 VDC Max switching current 2 A Min switching current 1 mA at 10 mVDC Ambient conditions Ambient temperature 0 to 50 C Transport and storage temperature 20 to 60 C Humidity 90 not condensing Tests and certificates EC Declaration of Conformity Yes Conformity standards EN 61000 6 2 2006 05 01 EN 61000 6 4 01 11 2007 8 320 Technical data