8 1 2015 BRG PREMANT district heating pipe PRE Subject to technical changes Bend with equal legs 90 6 305 20 0 Dd st L R 90 D outer diameter of casing pipe d outer diameter of medium pipe s wall thickness of medium pipe t insulation thickness Nominal Steel Leg length Design Insulation thickness 1 Insulation thickness 2 Insulation thickness 3 width pipe DN d L DE D D D mm mm mm kg mm kg mm kg 20 26 9 1000 5D 90 5 3 110 6 1 125 6 7 25 33 7 1000 5D 90 6 1 110 6 9 125 7 5 32 42 4 1000 5D 110 8 4 125 9 0 140 9 7 40 48 3 1000 5D 110 9 2 125 9 8 140 10 4 50 60 3 1000 5D 125 12 1 140 12 7 160 13 7 65 76 1 1000 5D 140 14 8 160 15 7 180 16 8 80 88 9 1000 5D 160 18 9 180 19 9 200 21 0 100 114 3 1000 5D 200 25 2 225 26 7 250 29 3 125 139 7 1000 5D 225 30 1 250 32 7 280 35 0 150 168 3 1000 5D 250 39 4 280 41 6 315 46 0 200 219 1 1000 5D 315 57 4 355 61 1 400 65 5 250 273 0 1000 3D 400 78 7 450 85 2 500 92 6 300 323 9 1000 3D 450 100 0 500 108 0 560 118 0 350 355 6 1000 3D 500 111 0 560 121 0 630 133 0 400 406 4 1000 3D 560 139 0 630 151 0 670 179 0 450 457 2 1100 3D 630 177 0 670 186 0 710 217 0 500 508 0 1200 3D 710 225 0 800 249 0 900 305 0 600 610 0 1300 3D 800 314 0 900 342 0 1000 410 0 700 711 0 1500 3D 900 463 0 1000 500 0 1100 541 0 800 813 0 1700 3D 1000 647 0 1100 694 0 1200 748 0 PREMANT Figures in mm DE The design of the radius is acc EN 10253 2 3 3 DE 2R d