21 8 2014 FLEXWELL district heating cable FHK Subject to technical changes 5 530 Installation through protective pipes FHK PVC PE AZ sewage pipe Min play 40 mm Protective pipe made of steel4 or concrete Skid distance Lmax 1 0 m from end Plastic skid Min play 40 mm FHK 1 after consulting BRUGG Pipe Systems 2 Min coverage height for SLW 60 0 80 m for SLW 30 or below a road surface 0 60 m 3 Min coverage 0 60 m 4 Joints without root seam Figure 2 Installing FHK through straight running protective pipes without offset using skids Max length of protective pipe 50 m1 Figure 1 Installing FHK through straight running protective pipes without offset not using skids Max length of protective pipe 50 m1 FLEXWELL district heating cable type 30 91 39 116 60 148 75 171 98 220 200 310 98 171 127 220 147 220 FHK casing pipe Ø max mm 95 121 156 178 233 313 Skid distance L m 2 00 2 00 2 50 3 00 3 00 4 00 without skids PVC sewage pipe to DIN 19 534 2 mm 125 x 3 160 x 3 6 200 x 4 5 250 x 6 1 315 x 7 7 400 x 9 8 Play between FHK and PVC pipe mm 24 32 35 60 67 67 AZ sewage pipe to DIN 19 850 2 mm 141 x 8 168 x 9 220 x 10 274 x 12 328 x 14 436 x 18 Inner pipe Ø mm 125 150 200 250 300 400 Play between FHK and AZ pipe mm 30 29 44 72 67 87 with skids Steel pipe to DIN 2458 3 4 mm 168 3 x 4 219 1 x 4 5 219 1 x 4 5 273 x 5 323 9 x 5 6 406 4 x 6 3 Inner pipe Ø mm 160 210 210 263 313 394 Skid company Frankenplastik 3 S19 4 S19 4 T19 2 F 1 G25 3 F 1 G25 4 F 1 G25 Play between FHK and pipe mm 27 51 20 35 30 31 Plug in sleeve for PVC sewage pipe PE sewage pipe AZ sewage pipe