8 1 2015 INT CASAFLEX district heating pipe CFL Subject to technical changes Entry into building Fixed point forces CASAFLEX district heating pipe is a self compensating statically resolved system i e it accom modates thermally induced changes in length within the system The system itself only has a limited ability to accommodate loads and deformations acting from outside Connections to conventional systems must be executed on a low load basis The following fixed point forces must be taken into account for each pipe depending on self compensation and inner pressure 4 515 Fixed point forces per pipe Type F F F F F F 6 bar 10 bar 16 bar 21 bar 25 bar 37 5 bar KN KN KN KN KN KN DN 20 0 3 0 5 0 8 1 0 1 2 1 8 DN 25 0 5 0 8 1 4 1 8 2 1 3 2 DN 32 0 8 1 4 2 2 2 9 3 5 5 3 DN 40 1 3 2 1 3 4 4 5 5 4 8 1 DN 50 1 9 3 2 5 1 6 7 8 0 12 0 DN 65 3 1 5 2 8 3 10 9 12 9 19 4 DN 80 5 1 8 5 13 7 17 9 21 3 32 0 DN 100 8 6 14 4 23 0 30 2 36 0 54 0 test pressure The fixed points forces will be influenced by structural conditions please contact our technology in advance