8 1 2015 INT CASAFLEX district heating pipe CFL Subject to technical changes 4 120 CASAFLEX DUO range Structure 1 Stainless steel carrier pipe 2 PIR foam 3 Expanded metal mesh 4 Barrier film 5 PE LD casing 6 Monitoring wires Type DN Inches Inner pipe Outer casing Minimum Volume Weight Maximum delivery lengths d x d1 x s D Bending radius Inner pipe Coil1 Coil2 Coil3 Coil4 mm mm m l m kg m m m m 22 22 111 20 25 x 22 x 0 3 111 1 1 0 44 2 5 205 290 360 500 30 30 126 25 1 34 x 30 x 0 3 126 1 4 0 80 3 1 155 230 280 340 39 39 142 32 1 44 x 39 x 0 4 142 1 5 1 35 3 7 100 150 200 300 48 48 162 40 1 55 x 48 x 0 5 162 1 8 2 04 4 2 55 100 145 190 60 60 182 50 2 66 x 60 x 0 5 182 2 0 3 12 5 1 55 80 Max permitted operating temp Tmax 130 C not available in Germany 1 Coil dimensions Ø 2800 x 800 mm width 2 Coil dimensions Ø 2800 x 1200 mm width 3 Coil dimensions Ø 3000 x 1200 mm width 4 Coil dimensions Ø 3000 x 1600 mm width just ex work Wunstorf Supplied in drums on request Heating 16 bar CASAFLEX DUO 1 2 3 4 56 d D d 1 s

Vorschau Katalog_e_12.8. Seite 137
Hinweis: Dies ist eine maschinenlesbare No-Flash Ansicht.
Klicken Sie hier um zur Online-Version zu gelangen.