16 12 2013 EIGERFLEX CPE Subject to technical changes 15 cm 15 cm 40 cm EIGERFLEX 3 510 FSB connection technology Sleeve joint 1 Planning 2 Preparation 3 Sleeve joint Connect the cables according to the installation instructions Remove 40 cm of insulation at the ends and carefully expose the strip Then shorten the inner pipe to length as shown in illustration 2 Shorten as shown in illustration 2 Figure 1 Figure 2 max 100 m max 100 m max 100 m L 100 m Continous joint L 100 m Separation Supply Connection strip End closure Supply End closure Supply Continuous joint L 100 m Separation L 100 mConnection strip Screwed joint or welded sleeve 30 cm 30 cm 30 cm Protect heating strip against moisture EIGERFLEX EIGERFLEX EIGERFLEX EIGERFLEX