16 12 2013 EIGERFLEX CPE Subject to technical changes 3 380 Building entry Wall leadthrough Core bores cement pipe liners PE connection piece see sheet CPE 3 350 End cap see sheet CPE 3 365 EIGERFLEX pipe see sheet CPE 3 115 3 120 D EIGERFLEX 80 mm Core bores Core bores Perfect bores are required for installation As hairline cracks may be present in the concrete or result from drilling it is advisable to seal the entire length of the borehole wall with suitable sealant such as AQUAGARD Tightness can only be guaranteed if this recommendation is followed Outer casing D1 Ø D mm mm 76 150 91 150 111 200 126 200 162 250 Key 1 EIGERFLEX 2 Sealing set single seal width 1 x 40 mm Shore hardness D35 3 Sealing set double seal width 2 x 40 mm Shore hardness D35 4 Liner pipe made of fiber cement or coated core bore Suitable for pressure from water up to 0 5 bar D 1